cast iron round sewer manhole cover d400 Ø716/615 mm

Poklop litinový D400. Horní pohled
PARAMETERVALUE
StandardEN124-2 : 2015
EN 124 ClassD 400
Maximum load40 tons
Materialspheroidal cast iron EN-GJS-500-7
Frame diameter716 mm
Cover diameter615 mm
Locking system2 locks
Total weight80 kg
Shaperound
Available coloursblack
Výkres víka poklopy litinového D400. Vnější pohled
Drawing of the round D400 manhole cover lid. External view
Výkres víka poklopy litinového D400. Horní pohled
Drawing of the round D400 manhole cover lid. Top view
Výkres víka poklopy litinového D400. Řez
Drawing of the round D400 manhole cover lid. Section view
Výkres rámu poklopy litinového D400. Průrez A-A
Drawing of the round D400 manhole cover frame. Cross-section A-А
Výkres rámu poklopy litinového D400. Průrez C-C
Drawing of the round D400 manhole cover frame. Cross-section C-C
Výkres rámu poklopa B125 - Průrez
Drawing of the round D400 manhole cover frame. Cross-section B-B

Before installation, check that the following components are included:

  • manhole cover with lid (or cap),

  • mounting brackets or anchor holes (if applicable),

  • load rating label (class A15–D400 according to EN 124),

  • sealing element (if applicable).

  • Clean the seating surface from dirt, remnants of old material, and moisture.

  • Check that the shaft collar is in good condition and free of cracks.

  • For cast iron manhole covers, a concrete or reinforced concrete base is required.

  • Essential for cast iron manhole covers due to their weight and load!
  • Minimum concrete thickness: 10–20 cm depending on the substrate.
  • Recommended concrete: C20/25 or higher.
  • Possible reinforcement with a steel mesh of 100×100 mm, Ø6–8 mm.
  • The diameter of the concrete surface should exceed the manhole cover frame diameter by at least 10–15 cm.
  • Insert the manhole cover frame to the desired height.
  • Level it evenly.
  • Position it correctly – the lid hinge should face the sidewalk, not the roadway.
  • Place the lid and ensure it fits properly and does not wobble.
  • Cast iron manhole covers are fixed either by concreting or with anchor bolts (depending on the frame type).

  • For improved sealing or noise reduction, a gasket can be installed (if the design allows).

  • Allow the concrete to cure for at least 24–48 hours (depending on the temperature) before applying any load.